YC-98S1 Portable Three Phase Standard Meter

Brand Name : GENY

Model Number : YC89S1

Certification : ISO, CE

Place of Origin : CHINA

Payment Terms : L/C,T/T,D/P

Model NO. : YC98S1

Voltage Output : 30V-480V

Current Output : 0.05-10A

LCD Display : With LCD Display

Contact Now

YC-98S1 Portable Three Phase Standard Meter



The instrument YC98S1 is used to calibrate three phase, single phase, active or reactive energy meter who comply with GB/T17215.211 (IEC62052-11), GB/T17215.311 /321/322/323 (IEC62053-11/21/22/23), and also it can be used as voltage, current and power meter to measure AC parameter of three phase power grid.

This portable three phase standard meter comply to GB/T11150-2001 (IEC60736:2001), GB/T4793.2-2008 (IEC61010-1:2001)


Product Parameters



Test Voltage (Full Wave & Fundamental Wave)



Range

0~500V



Error

±0.05% (0.1%)



Harmonic

2nd ~ 51st



Test Current (Full Wave & Fundamental Wave)



Range (direct connection)

0.025A ~ 12A (Ie=5A)



Range (100AClamp CT)

0.5~120A (Ie=100A,usage range=0.01Ie~2.4Ie)

(Optional: Ie=5A, 500A, 1000A)



Error (direct connection)

±0.05% (0.1%)



Error (100AClamp CT)

±0.2%(5A,100A) ±0.5% (other)



Harmonic

2nd ~ 51st



Starting current

0.05%Ie



Power Measure Error (Full Wave & Fundamental Wave)



Active Power (Direct connection)

±0.05%



Active Power (100A ClampCT)

±0.2%(5A,100A) ±0.5% (other)



Reactive Power (Direct connection)

±0.1%



Reactive Power (100A ClampCT)

±0.5%(5A,100A) ±1.0% (other)



Energy Measure Error (Full Wave & Fundamental Wave)

Active Energy (Direct connection)

±0.05% (±0.1%)

Active Energy (100A ClampCT)

±0.2%(5A,100A) ±0.5% (other)

Reactive Energy (Direct connection)

±0.1%

Reactive Energy (100A ClampCT)

±0.5%(5A,100A) ±1.0% (other)

Error (Harmonic Wave)

Direct Connection

kWh,U, I, P, Q, S

±0.2%H (H=1+0.01k, k=2~51)

Clamp CT 5A/100A

kWh,U, I, P, Q, S

±0.5%H (H=1+0.01k, k=2~51)

Cycle Output Current for 5A CCT’s Self Calibration

0.05A,0.1A,0.25A,0.5A,1A,2.5A,5A

Error of 5ACCT’s Self Calibration

(linear and phase error)

±0.1%

Clamp CT 500A/1000A

kWh,U, I, P, Q, S

±1.0%H (H=1+0.01k, k=2~51)

Error - Others

Ratio Measurement

±0.5%

Voltage Influence

<±0.01%

Frequency Influence

<±0.01%

Temperature Influence

<±0.01%/℃

24h Accuracy Influence

<±0.01%

Harmonic Influence

<±0.01%

Phase angle

Range

-180°~ 180°

Error

<±0.1°

Frequency

Range

45 ~ 65Hz

Error

±0.01Hz

Pulse output

Inner High frequency (CH)

Direct connection

1.8x109 P/kWh

Clamp CT

1.8x109 *(5/Ie)P/kWh

Low frequency output

Direct connection

3600P, 36000P,

360000P/kWh(kvarh, kVAh)

Clamp CT

3600P, 36000P, 360000P

*(5/Ie)P/kWh(kvarh, kVAh)

Pulse ratio

1:1

Output level

+5V (can be adjusted according to request)

Pulse input

Input Channel

2

Input level

5 ~ 10V

Max Pulse Input frequency

Max. 10kHz

Display

Resolution

7’’TFT Touch Screen

System

Windows CE

Other

Voltage supply mode

External power, Tested circuit, Battery

Working power supply

AC 55~600V

Voltage Withstand

4.0kV (voltage ¤t terminals, power supply & low voltage terminals)

EFT(Electrical Fast Transient)

2.0kV

IP Level

IP51

Surge

2.0kV (common mode), 2.0kV (different mode)

Power on Stability Time

< 3mins

Chargeable battery

11.1V 3000mAh

Power Consumption

<9W

Operation Temperature

Temperature -20℃ ~ +55℃, humidity 40% ~ 95%

Storage Temperature

Temperature -40℃ ~ +80℃, humidity 40% ~ 95%

Dimension (mm) (W×H×D)

Main

245×150×50

Carry case

425×336×196

Weight (kg)

Main

2

Whole set

10



Test Functions


1.Multi-Meter Testing:

Tests one or two meters simultaneously, with error display precise to five digits and three decimal places.

2.Automated/Manual Testing:

Automated test sequence for electronic and electromechanical meters.

Manual control via start/stop button or firmware.

3.Data Calculation and Display:

Displays full wave, fundamental wave, harmonic wave data, and U, I, P, Q, VA, phase angle.

Shows positive/negative sequence, zero sequence, and harmonic content.

4.Energy Accuracy Testing:

Tests active/reactive energy for full wave, fundamental wave, and harmonic wave meters.

Tests apparent energy accuracy.

5.Dual-Channel Pulse Testing:

Simultaneous testing of two channels with different pulse constants and modes.

6.Wiring Identification and Energy Accumulation:

Identifies wiring without load.

Measures energy meters without pulse output.

7.Dial Test Function:

Time method or energy method available.

8.Waveform and Vector Display:

Displays vector diagrams and three-phase voltage/current waveforms.

9.Wrong Wiring Identification:

Detects 48 types of three-phase and 96 types of four-wire connections.

Identifies CT secondary crossing wiring.

10.Wiring Simulation and Training:

Simulates wiring scenarios for training and parameter revision without voltage/current signals.


Harmonic Functions


1.Harmonic Analysis:

Calculates harmonic compound of U, I, P, Q, VA and their percentages.

Analyzes up to 51st harmonic (+PH/-PH) and their impact on meter metrology.

2.Full Wave Reactive Power:

Algebraic sum of fundamental and harmonic waves.

Avoids errors from 90-degree phase shift method by selecting harmonic wave numbers based on meter bandwidth.


YC-98S1 Portable Three Phase Standard Meter

YC-98S1 Portable Three Phase Standard Meter

YC-98S1 Portable Three Phase Standard Meter



China YC-98S1 Portable Three Phase Standard Meter wholesale

YC-98S1 Portable Three Phase Standard Meter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou GENY Electric Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0